Installation guide

68 Brocade ServerIron ADX Installation Guide
53-1003445-01
Hardware specifications
A
Table 6 lists the operating voltage and current ratings for ServerIron ADX 1000.
.
Table 7 lists the operating voltage and current ratings for ServerIron ADX 4000/8000/10000.
.
Physical dimensions
Table 8 provides the physical dimensions for the ServerIron ADX chassis.
Operating environment
Table 9 provides the operating environment specifications for the ServerIron ADX chassis.
ServerIron ADX 8000 fan tray 137W
SSL Expansion module 65W
TABLE 6 ServerIron ADX 1000 and ServerIron ADX 1000F operating voltage and current ratings
Power Supply Input Voltage Range Input Current Inrush Current Maximum Output
AC 100-240Vac (85-264Vac) 7A max 30A peak @ 25º C 500W
DC -48Vdc (-40Vdc to -60Vdc) 15A max 25A peak @ 25
º C 500W
TABLE 7 ServerIron ADX 4000/8000/10000 operating voltage and current ratings
Power Supply Input Voltage Range Input Current Inrush Current Maximum Output
AC 100-240Vac (90-264Vac) 16A max 40A peak @ 25º C 1200W
DC -48Vdc (-36Vdc to -72Vdc) <
35A @ -48VDCin 45A peak @ 25º C 1200W
TABLE 8 Physical Dimensions
ServerIron ADX Chassis Height Width Depth Weight (fully-loaded)
ServerIron ADX 1000 1.71 (4.3. cm) 17.45" (44.3 cm) 18.06 (45.8 cm) 37.48 lbs (17.00 kg)
ServerIron ADX 1000F 1.71 (4.3. cm) 17.45" (44.3 cm) 18.06 (45.8 cm) 37.48 lbs (17.00 kg)
ServerIron ADX 4000 6.96 (17.7 cm) 17.45" (44.3 cm) 17.5" ( 44.5 cm) 53.95 lbs (24.47 kg)
ServerIron ADX 8000 13.96" (35.5 cm) 17.45" (44.3 cm) 17.5" ( 44.5 cm) 92.45 lbs (42 kg)
ServerIron ADX 10000 17.45” (44.3 cm) 17.45" (44.3 cm) 21.971 (55.78 cm) 111.8 lbs (50.71)
TABLE 9 Operating Environment
Operating Temperature Relative Humidity Operating Altitude
32° – 104° F (0° – 40° C) 5 to 90%, at 104° F (40° C), non-condensing 0 – 6600 ft (0 – 2012 meters)
TABLE 5 Wattage Consumed by Individual Modules
ServerIron ADX Chassis Maximum Power Consumption, in
Watts