Installation guide
32 Brocade ServerIron ADX Installation Guide
53-1003445-01
Installing ServerIron ADX
2
6. Locate the 5 mounting holes and using a Phillips screwdriver fasten the SSL Expansion module
to the ServerIron ADX Management Module with the five screws.
FIGURE 24 Installing the five screws
7. Once you have installed the management module with the new SSL expansion module in the
ServerIron ADX chassis, run the show module command to verify that the system has
recognized the module.
The SSL expansion module will be shown in the ServerIron Management Module slot as either
a "DOB SSLN" or "DOB SSL6" with a status READY as shown in the example below:
NOTE
One of two types of SSL expansion module installed can be displayed. An SSLN indicates the
new SSL expansion module is installed while an SSL6 indicates the older SSL expansion
module is installed.
1 4-40 x 3/8 Phillips drive pan head screws
ServerIronADX# show module
Slot Module Status Ports Starting MAC
slot-lc1: Line Card 12x1G Copper RUNNING 12 0004.90a0.4000
slot-lc2:
slot-mp: ServerIron Management Mod ACTIVE 1 0004.90a0.4000
DOB SSLN READY
slot-sf: ServerIron Switch Fabric Mod RUNNING 0
slot-asm1: ServerIron 8BP App Switch Mod RUNNING 0
slot-asm2: