Installation guide

Brocade ServerIron ADX Installation Guide 25
53-1003445-01
Installing ServerIron ADX
2
The ServerIron ADX 10000 chassis ships with the following components installed (see shaded slots
in Figure 18):
Two SFMs
Fan tray
Two power supplies
FIGURE 18 Slot assignments for the ServerIron ADX 10000 Chassis
The slot assignments for the ServerIron ADX 8000 chassis are described in Appendix B, “ServerIron
ADX 8000”.
NOTE
If you are installing 2 management modules in a ServerIron ADX 10000 chassis, they both must be
of the same type (MM1 or MM2). If you install two different types of management module, only the
management module in slot MM 1 will be brought up.
CAUTION
If you do not install a module in a slot, you must leave the blank slot module installed in the slot.
If you run the chassis with an uncovered slot, the system may overheat.
Before installing a module in a ServerIron ADX 4000, ServerIron ADX 8000 or ServerIron ADX
10000 chassis, have the following on hand:
An ESD wrist strap with a plug for connection to the ESD connector on the chassis.
NOTE
For safety reasons, the ESD wrist strap should contain a 1M ohm series resistor.
A large flat-head screwdriver.