Installation guide

24 Brocade ServerIron ADX Installation Guide
53-1003445-01
Installing ServerIron ADX
2
CAUTION
Slot ordering and type for ServerIron ADX 4000, ServerIron ADX 8000 and ServerIron ADX 10000
is important. Each module is keyed according to type. Do not attempt to force a module into a slot
that is not intended for that module type. Refer to Figure 17 and Figure 18 for correct module
placement.
- Application Switch Modules (ASM) must occupy only slots indicated as ASM slots.
- Management Modules (MM) must occupy only slots that are indicated as MM slot.
- Switch Fabric Modules (SFM) must occupy only slots that are indicated as SFM slots.
- Ethernet Interface Modules must occupy only slots that are indicated as INTERFACE MODULE
slots.
- Power Supplies must be installed only in the slots indicated as PS slots.
All components (Ethernet Interface Module, ASM, MM, SFM, and PS) must be added to
ServerIron ADX 4000, ServerIron ADX 8000 or ServerIron ADX 10000 in the slots designed for
them. For example, a MM must be installed in one of the MM slots. Ethernet Interface Modules
must be installed in the slots marked for interface modules.
The ServerIron ADX 4000 chassis ships with the following components installed (see shaded slots
in Figure 17):
One SFM
Fan tray
One power supply
FIGURE 17 Slot assignments for the ServerIron ADX 4000 Chassis