User guide
35Fabric OS 4.4.x release notes
Board won't boot all the way if it loses
its boot environmental Variables.
Console output would look like this:
The system is coming up, please wait...
Unable to read configuration data
WARNING: Failed to set EMAC
hardware addresses!
1) Start system.
2) Recover password.
3) Enter command shell.
Option? 0
Fixed.
For debugging usage, PortID in the
"portlogdump" should refer to the Area
number of the "switchshow" when
"Extended Edge PID" is set.
Fixed.
"Incompatible flow control" warning
messages should refer to the "Area
number" of the "switchshow" when
"Extended Edge PID" (format 2) is set.
Fixed.
crossporttest -nframes 1000 and
failover, got OOPS.
This problem only happens on a Core
Switch 2/64 when crossporttest -nframe
1000 is executed on switch 1 (does not
happen when test is executed on switch
0) issue hafailover, then OOPS occurs
on the current standby CP.
Fixed.
Misleading PCI debug message
generated during slot scan.
Error message "db_scan_slot: failed to
read header type func 0 dev 14 bus 2,
ret= -22" observed when powering slot
off then back on.
Fixed.
Table 5 Closed issues for Fabric OS 4.2.2a (continued)
Fabric OS 4.2.2a Issue Status