User guide
29Fabric OS 4.4.x release notes
Some CHPIDs are not able to access
the devices after an IOCDS change and
'config POR'. It appears that FLOGI to
the devices get F_RJT with reason
code x04. A port disable and port
enable at the switch for the CHIPID
corrects the problem.
Fixed.
Using Script continuously telnet
login/logout, some sessions fail with
timeout.
Fixed.
When POST is running, reset the micro
switch on the active CP. The standby
CP will become active CP now.
However, the console of this current
active CP will show an error message
"Critical PLATFORM-CP_SERVICE, 1,
Internal routing error. Disabling
switch(es)". When the POST test are
successfully done, the switch is in
"disable" state.
Fixed.
Host lost connection to storage after
"host reboot" stress script testing.
Fixed.
Commands not permitted in the present
login must display "Permission denied"
message.
Fixed.
perfShowEEMonitor slot/port, interval of
5 will print out one line of all ZERO
when it reach the RX and TX count
some where around 0x40000000.
Fixed.
SNMP FRU history trap is not always
generated as expected.
Fixed.
Table 5 Closed issues for Fabric OS 4.2.2a (continued)
Fabric OS 4.2.2a Issue Status