User guide
17Fabric OS 4.4.x release notes
Logging,
supportFTP
command
When setting the automatic FTP IP address, userid, password, and
associated directory path for use with the supportFtp command, the
parameters are not checked immediately for validity. Generate a manual
trace dump to confirm the FTP transfer immediately. First, use supportFtp to
set up FTP parameters. Next, use traceFtp -e to enable automatic
transfer of the trace dumps. Finally, use the traceDump -n command to
create a dump. Confirm that the FTP transfer was successful.
Logging,
chassisName
command
Run the chassisName command before upgrading to Fabric OS v4.4 so
that any subsequent error messages related to the chassis and switch
services will be logged correctly to the system error log. For further
information, refer to the
HP StorageWorks Fabric OS 4.4.x procedures
user guide.
HP StorageWorks
8-Port Upgrade License
A SAN Switch 4/32 with a 16-port factory configuration requires a
HP
StorageWorks 8-Port Upgrade License
, Part Number T3677A, in order to
enable and use switch ports 16 thru 31.
rsh and rlogin The programs rsh and rlogin are not supported in this release. If you try to
use an rsh or rlogin client, Fabric OS rejects the login attempt; however,
because most rsh and rlogin clients continue to retry the login for several
seconds before timing out, your system appears to hang. Secure
connections are available via a Secure Shell (SS).
Security: error counter Telnet security errors that arrive in quick succession are recorded as a
single violation by the Telnet error counter. For example, a login error from
a host whose IP address is 192.168.44.247 is logged as follows:
Security violation: Login failure attempt via TELNET/SSH/RSH. IP Addr:
192.168.44.247
If another login violation occurs immediately, the message remains the
same and only the error counter is incremented.
Security: FCS list Adding switches to the FCS list does not automatically join the switches in
a secure fabric. Add the switches to the FCS list of the new switches and
the target fabric. Reset the version stamp to 0 and either reset the E_Ports
or perform a switch disable and enable for the switches to join.
Table 4 Fabric OS area information (continued)
Fabric OS Area Description