Specifications
HP StorageWorks Fabric OS 4.x Fabric Watch user guide, part number: AA-RVJ0A-TE30
The following row replaces the existing row “Flash” in Table 28, “Resource Class Threshold
Defaults,” on page 98:
Invalid Transmission
Word
Monitors the
number of invalid
words transmitted
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-between: 0
Informative
Informative
Out of range
In range
Link Failure Count Monitors the
number of link
failures
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-between: 0
Informative
Informative
Out of range
In range
Loss of Signal Count Monitors the
number of signal
loss errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-between: 0
Informative
Informative
Out of range
In range
Primitive Sequence
Protocol Errors
Monitors the
number of primitive
sequence errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-between: 0
Informative
Informative
Out of range
In range
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold State
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold State
Flash Monitors the
percentage of
compact flash used
Unit: Percent (%)
Time Base: none
Low: 0
High: 85
Buffer: 0
Changed: 0
Below: 3
Above: 3
In-between: 1
Informative
Informative
Out of range
In range