Table 9 Fabric OS 7.0.0 closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.0.On an HP StorageWorks 4/256 SAN Director running Fabric OS 6.4.0a
or later, an unstable link triggers a continuous timeout/discard
frame/unroutable frame tracing causing the CPU to be too busy to process
requests.
Fixed in Fabric OS 7.0.0.In an FCIP environment, a replication device port may fail with a panic
when FCIP FastWrite is used on HP 1606 SAN Extension Switch tunnels.
Workaround prior to upgrade: Reboot the
switch through the CLI command to
recover.
Switches running Fabric OS 6.4.x lose manageability from WebTools/DCFM
and all LED's on the switch are amber. This is caused by the SNMPD not
running after system resources are depleted from the upgrade. Switch traffic
Fixed in Fabric OS 7.0.0.
is not impacted, and it is still possible to manage the switches via the CLI.
This affects switches only with no impact to directors.
Fixed in Fabric OS 7.0.0.Changing linkcost to maximum value of 65,535 causes fabric connectivity
problems because all routes are lost in the fabric.
Workaround prior to upgrade: To avoid
the corruption code flow, instead of
Zone corruption occurs when copying all zonesets from one AD to another
using "zone --copy <ADD_NUM>”. Subsequent zoning related operations
may result in zone termination and switch reboot. copying all zonesets at once from one AD
to another (using zone --copy
<ADD_NUM>), copy zonesets one by one
using zone --copy <ADD_NUM>
source_zoneset>
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.Customers may experience a large number of CRC errors and reduced
performance on data transfers when connecting to tape drives on an HP
8/40 SAN Switch with Finisar optics.
Fixed in Fabric OS 7.0.0.No error message was output when an incorrect syntax was used for the
"cryptocfg --create -container" command . Subsequently, the customer had
difficulty in configuring the HP StorageWorks Encryption SAN Switch
because the incorrect syntax in the CLI creation of a container caused a
problem when trying to define LUNs.
Fixed in Fabric OS 7.0.0.The help text in Fabric OS 6.3.0 does not reflect the trackchangesset
command is deprecated. Even though the command can still be entered, it
has no effect.
Fixed in Fabric OS 7.0.0.The HP StorageWorks DC04 SAN Director Switch is experiencing a high
rate of internal CRC errors on select links.
Fixed in Fabric OS 7.0.0.For both IPv4 and IPv6, the ipfilter tool incorrectly leaves unfiltered TCP and
UDP ports 1024-49151 (inclusive), as well as TCP ports 80 and 443. These
ports may not be blocked implicitly or explicitly.
Fixed in Fabric OS 7.0.0.In a FICON environment, customers may experience IFCCs from CUP due
to Address specific bit NOT being set.
Fixed in Fabric OS 7.0.0.In a FICON environment, an SNMP query of nodeRNIDPortType will indicate
n-port for E_Ports.
Fixed in Fabric OS 7.0.0.The HP 2408 FCoE Switch does not update the optics digital diagnostics
data during runtime. The 'show media' command does not show the TX/RX
power value correctly after the user disconnects and reconnects the optical
cable.
Fixed in Fabric OS 7.0.0.In Fabric OS 6.4.1b, the RMON alarm value for etherStatsOversizePkts is
not updated and is permanently set to 0.
Fixed in Fabric OS 7.0.0.Various configuration status are not reflected to configFile. When a policy
is modified by a user and uploaded via configUpload, the resulting
configFile does not reflect the updated policy.