User guide

needs to be set based on the application needs. If the local and remote circuit configurations
Keep Alive Timeout values do not match, the tunnel uses the lower of the two configured values.
The configured FCIP Circuit Keep Alive Timeout should be set to the same value on both ends
of the FCIP connections.
To perform the following operations, delete the FCIP configuration on the affected ports first:
Switching modes between 1 Gbps/10 Gbps/Dual
Moving VE/GE port between logical switches
Cleaning up the configuration before removing the blade
Inband Management on the HP 1606 SAN Extension Switch or HP DC SAN Director
Multiprotocol Extension Blade has the following restrictions:
Firmwaredownload over the Inband interface is not supported.
IPv6 addressing is not supported.
Fabric OS 7.0.0x supports up to six 1 Gbps circuits on HP 1606 SAN Extension Switch and
up to ten 1 Gbps circuits on HP DC SAN Director Multiprotocol Extension Blade per VE/FCIP
Tunnel on 1 GbE interfaces. As a best practice, the FC-traffic through VE tunnel should not
exceed recommended over-subscription guidelines. General guidelines are 2:1 over-subscription
without compression (for example, 1 Gbps FC traffic over 500 Mbps tunnel) and 4:1 with
compression.
Any firmware activation disrupts I/O traffic on FCIP links.
Under Traffic Isolation Zone, configurations with failover enabled, non-TI zone traffic uses the
dedicated path if no other E or VE paths through the fabric exist, or if the non-dedicated paths
are not the shortest paths. (A higher bandwidth tunnel with multiple circuits becomes the
shortest path compared to a single tunnel).
A VE/VEX Tunnel and E/EX FC port cannot connect to the same domain at the same time.
Latency measurements supported on FCIP Tunnels are for 1 GbE & 10 GbE a 200 ms round
trip time and 1% loss.
HP 1606 SAN Extension Switch supports Optical and Copper Media types on GE0 and GE1
interfaces. Copper Media type is default on GE0/GE1 ports and does not support auto-sense
functions.
When GE0 and GE1 have copper media connected, auto-negotiation must be enabled on
the other end of this port. The only speed that can be auto-negotiated with copper media is
1 Gbps.
After inserting a 4 Gbps SFP in GE ports of an HP DC SAN Director Multiprotocol Extension
Blade or HP 1606 SAN Extension Switch, sometimes sfpshow output might display Cannot
read serial data! . Removing and re-inserting the SFP should resolve this issue. HP
recommends that users perform sfpshow immediately after inserting the SFP and ensure SFP
is seated properly before connecting the cables.
When running Fabric OS 7.0.0a or later, if any of the following features are enabled in the
FCIP configuration, a downgrade operation to pre-Fabric OS 7.0.0a is blocked until the
features are removed from the FCIP configuration:
Inband Management
Multigigabit Circuit
Shared GE among Logical Switches
Auto-mode compression option
VE as XISL
10 GigE lossless failover
30