a host panic may occur and this configuration is not supported in the Fabric OS 6.3.1 or later
release.
Hot Code Load from Fabric OS 6.4.1a to Fabric OS 7.0.0c is supported. Cryptographic
operations and I/O are disrupted, but other layer 2 FC traffic is not disrupted.
Relative to the HP StorageWorks Encryption SAN Switch and an HP StorageWorks DC SAN
Backbone Director Switch / HP StorageWorks DC04 SAN Director Switch/ HP SN8000B
8-Slot SAN Backbone Director Switch, and the HP SN8000B 4-Slot SAN Director Switch with
HP StorageWorks DC Switch Encryption FC Blade, all nodes in the Encryption Group must
be at the same firmware level of Fabric OS 6.2 or later before starting a rekey or First Time
Encryption operation. Make sure that existing rekey or First Time Encryption operations complete
before upgrading any of the encryption products in the Encryption Group. And make sure
that the upgrade of all nodes in the Encryption Group completes before starting a rekey or
First Time Encryption operation.
To clean up the stale rekey information for the LUN, use one of the following methods:
Method 1:
1. Modify the LUN policy from encrypt to cleartext and commit. The LUN becomes
disabled.
2. Enable the LUN using cryptocfg --enable LUN. Modify the LUN policy from
clear-text to encrypt with enable_encexistingdata to enable the first
time encryption and do commit. This clears the stale rekey metadata on the LUN and
the LUN can be used again for encryption.
Method 2:
1. Remove the LUN from Crypto Target Container and commit.
2. Add the LUN back to the Crypto Target Container with LUN State=clear-text,
policy=encrypt and enable_encexistingdata set for enabling the First Time
Encryption and commit. This clears the stale rekey metadata on the LUN and the
LUN can be used again for encryption.
When disk and tape CTCs are hosted on the same encryption engine, re-keying cannot be
done while tape backup or restore operations are running. Re-keying operations must be
scheduled at a time that does not conflict with normal tape I/O operations. The LUNs should
not be configured with auto rekey option when single EE has disk and tape CTCs.
For new features added to encryption in Fabric OS 6.4.0, such as, disk device
decommissioning, combined disk-tape encryption support on the same encryption engine,
and redundant key ID metadata option for replication environments, all the nodes in the
encryption group must be running Fabric OS 6.4.0 or later versions of Fabric OS. Firmware
downgrade is prevented from Fabric OS 6.4.0 to an earlier version if one or more of these
features are in use.