Technical data
Fixed in Fabric OS 5.3.2
User cannot access switch through net-
work. If the contents of the /etc/in-
etd.conf file are modified, the file may
be deleted the next time the switch soft-
ware is upgraded.
Fixed in Fabric OS 5.3.2
Switch hit a rolling reboot due to RTE DB
inconsistency triggered by PCI scan fail-
ure on a failure blade during hafail-
over.
Fixed in Fabric OS 5.3.2
Workaround—Reboot the switch.
User may be unable to connect to HP
StorageWorks 4/32 SAN Switch from
SMI Agent and see error related to limit
of RPC handles open. RPC daemon indic-
ates it has reached its limit of RPC
handles, but netstat command does
not show active sessions from the SMI
Agent host.
Fixed in Fabric OS 5.3.2
Web Tools zoning breaks when third
party storage virtualization appliance
changed to standby mode.
Fixed in Fabric OS 5.3.2
Panic occurred during attempted multi-
count write to compact flash.
Fixed in Fabric OS 5.3.2
Invalid route table causes Class 3 Frame
to drop. This happens on HP Storage-
Works B-Series Multi-protocol Router
Blade/HP StorageWorks 400 Multi-pro-
tocol Router with Ex port.
Fixed in Fabric OS 5.3.2
Workaround—Make sure both CPs are upgraded together.
evmd panic occurs when upgrading from
Fabric OS 5.1.x to Fabric OS 5.3.x.
Fixed in Fabric OS 5.3.2
Frame drop is observed on 4Gb and
8Gb switches due to a time window
when a port in a trunk goes offline and
route is not properly recalculated.
Fixed in Fabric OS 5.3.2
supportsave during serviceability test
detected memory corruption on FCR-
based switch.
Fixed in Fabric OS 5.3.2
CAL EnumerateSelectedInstances
on Brocade_ISL is returning wrong
linkMembers for McData switch.
Fixed in Fabric OS 5.3.2
When default zoning is set to All Access,
a potential race condition could cause
the rejection of the NPIV PLOGI.
Fixed in Fabric OS 5.3.2
Auditcfg not persistent through hare-
boot.
Fixed in Fabric OS 5.3.2
Workaround—Run hareboot/hafailover.
Unable to run portstatsclear on a
switch.
HP StorageWorks Fabric OS 5.3.2 release notes 21