Technical data
Closed with Code Change in Fabric OS v7.0.0b
Fabric OS v7.0.1a Release Notes v1.0 Page 66 of 74
Defect ID: DEFECT000354560
Technical Severity: Medium
Summary: Failed tape jobs encountered with tape pipelining enabled when utilizing a FICON to ESCON
converter
Symptom: Tape jobs intermittently fail with tape pipelining enabled when utilizing a FICON to ESCON
converter.
Workaround: Disable tape pipelining
Feature: Field Escalation
Function: FCIP
Probability: Medium
Found in Release: FOS6.4.2
Where Else Fixed: FOS6.4.2 a
Defect ID: DEFECT000354750
Technical Severity: Medium
Summary: Unable to access the boot prom on a 5480 when it is installed in a C-7000 chassis
Symptom: Unable to access the boot prom on a 5480.
Feature: UNDETERMINED
Function: UNDER REVIEW
Probability: Low
Found in Release: FOS6.3.1
Service Request ID: 589577
Defect ID: DEFECT000354967
Technical Severity: Medium
Summary: WebTools: When attempting to upgrade a switch in IM2/IM3 to FOS v7.0, fail message
should direct user to Interoperability tab to change switch to Brocade Native Fabric Mode
Symptom: When upgrading a switch in IM2/IM3 to v7.0 via WebTools, the failure message references
the interopmode command, but does not provide WebTools instructions.
Feature: FC Services
Function: Other
Probability: Medium
Found in Release: FOS7.0.0
Defect ID: DEFECT000355888
Technical Severity: Medium
Summary: D_Port (CLI): Caution message should not mention Brocade Branded SFPs.
Symptom: Caution message seen when executing D_Port CLI mentions "only Brocade Branded SFPs".
Feature: FC Services
Function: D-port
Probability: High
Found in Release: FOS7.0.0
Defect ID: DEFECT000355909
Technical Severity: Medium
Summary: perfaddusermonitor/fmconfig not correctly counting SOFf frames
Symptom: SOFf frame counter is not detecting SOFf frame ingress/egress when filter monitor is
enabled.
Feature: Field Escalation
Function: ASIC Driver
Probability: High
Found in Release: FOS6.4.2
Service Request ID: 632819