Technical data
Fabric OS v7.0.1a Release Notes v1.0 Page 58 of 74
Closed with Code Change in Fabric OS v7.0.0c – GA November 18, 2011
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
November 18, 2011 in Fabric OS v7.0.0c
Defect ID: DEFECT000354348
Technical Severity: High
Summary: Not receiving the RAS log Cx-5021 message for front port partial credit loss on an EX-Port
Symptom: Customer will be unaware if EX_Ports are leaking credit.
Feature: 8G FCR
Function: FCR Daemon
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000364137
Technical Severity: High
Summary: FabricWatch Port Class is not monitoring ICL ports. E-Port Class monitors are monitoring
ICL ports.
Symptom: ICL Ports will not report any threshold warnings and will not be fenced for Port Class
attributes.
Feature: FABRIC WATCH
Function: PORT FENCING
Probability: High
Found in Release: FOS7.0.0
Defect ID: DEFECT000364799
Technical Severity: High
Summary: After downgrading from v7.0.0 to v6.4.x, a route rebalance or recalculation will cause some
ICL paths to be blocked.
Symptom: Connectivity between devices lost after route change.
Workaround: Disable all ICL ports and then enable all ICL ports.
Feature: UNDETERMINED
Function: UNDER REVIEW
Probability: High
Found in Release: FOS6.4.2
Defect ID: DEFECT000364945
Technical Severity: High
Summary: Unable create 4th tunnel with crossport circuits in chassis with multiple FX8-24 blades.
Symptom: Unable create more than three tunnels with crossport circuit configuration in a chassis with
multiple FX8-24 blades.
Feature: FCIP
Function: Other
Probability: High
Found in Release: FOS7.0.0