Technical data

Closed with Code Change in Fabric OS v7.0.1
Fabric OS v7.0.1a Release Notes v1.0 Page 50 of 74
Defect ID: DEFECT000335811
Technical Severity: Medium
Summary: Brocade 5450 switches crashed when latest version of enclosure management SW was
used.
Symptom: Brocade 5450 platform may panic if used with newer version of MMB that uses new ISMIC
block that was previously unsupported.
Workaround: Use initial qualified MMB version.
Feature: Field Escalation
Function: Panic / OOM
Probability: Low
Found in Release: FOS6.2.0
Service Request ID: 530085
Where Else Fixed: FOS6.4.2 a
Defect ID: DEFECT000336933
Technical Severity: Medium
Summary: Switch sends ELP to device after the device sends FLOGI during power-up sequence
Symptom: When connected to 4G switch, during a specific storage device power-up sequence, host
cannot access target.
Feature: Field Escalation
Function: ASIC Driver
Probability: Low
Found in Release: FOS6.1.2
Service Request ID: 444823
Where Else Fixed: FOS6.4.2
Defect ID: DEFECT000339701
Technical Severity: Medium
Summary: Even after removing the device from the LSAN zoning, nsinfo.html for switch is not updated
with removed devices.
Symptom: nsinfo.html may not be updated with devices that have been removed from an LSAN zone.
Feature: 8G FCR
Function: FCR Daemon
Probability: Medium
Found in Release: FOS6.4.2
Defect ID: DEFECT000342412
Technical Severity: Medium
Summary: TPERF session may not be able to be restarted until all user disabled GE ports on the test
tunnel are re-enabled.
Symptom: If a user disables GbE ports on a TPERF test tunnel while a TPERF session is in progress
and the TPERF session is subsequently terminated, TPERF may not be able to be restarted
until the disabled GbE ports are re-enabled.
When in this state, if the user attempts to re-start TPERF, they will get a message indicating
that a TPERF session is already in progress.
Feature: FCIP
Function: FCIP CLI
Probability: Low
Found in Release: FOS7.0.0