Technical data

Closed with Code Change in Fabric OS v7.0.1
Fabric OS v7.0.1a Release Notes v1.0 Page 49 of 74
Defect ID: DEFECT000375295
Technical Severity: High
Summary: F_Port stuck in Disabled (N-Port Offline for F-Port) after AG reboot
Symptom: F_Ports on some access gateways are stuck in F_Port Disabled state (N-Port Offline for F-
Port) and observe raslog reports: [AG-1005], FDISC response was dropped.
Feature: Field Escalation
Function: Access Gateway
Probability: Low
Found in Release: FOS6.2.2
Service Request ID: 684505
Defect ID: DEFECT000299540
Technical Severity: Medium
Summary: The manual_rekey -all command will not function in director-class chassis when multiple
EEs are present with access to the same LUN
Symptom: Manual rekey fails when there are DEK cluster LUNs hosted by both EEs from same
chassis.
Feature: Data Security
Function: Disk Encryption
Probability: Low
Found in Release: FOS6.3.0
Defect ID: DEFECT000317392
Technical Severity: Medium
Summary: systemverification failing on 7800.
Symptom: systemverfication test fails
Feature: Diagnostics
Function: Other
Probability: Low
Found in Release: FOS6.3.1
Where Else Fixed: FOS7.0.0 GA
Defect ID: DEFECT000319548
Technical Severity: Medium
Summary: ceeportloopbacktest and ceeportledtest does not properly process all parameters on the
Brocade 8000
Symptom: Customer cannot utilize all options of the CEE port diagnostic tests
Feature: Diagnostics
Function: Other
Probability: High
Found in Release: FOS6.4.0
Service Request ID: 451771
Where Else Fixed: FOS7.0.0 GA, FOS6.4.1 b