Technical data
Closed with Code Change in Fabric OS v7.0.1
Fabric OS v7.0.1a Release Notes v1.0 Page 45 of 74
Defect ID: DEFECT000351152
Technical Severity: High
Summary: Name server assert triggered switch panic
Symptom: Switch reboot or hafailover observed when Admin Domain (AD) database was not in sync
and there was port offline event on local/remote switch.
Feature: Field Escalation
Function: Fabric Services
Probability: Low
Found in Release: FOS6.4.1
Service Request ID: 618539
Where Else Fixed: FOS6.4.2 b GA
Defect ID: DEFECT000353445
Technical Severity: High
Summary: Out of band bulk requests (SMI) can cause Name Server to panic in frame redirection
environments.
Symptom: Multiple name server panics observed in conjunction with applications which performs
GXX_ID (such as GCS_ID) queries via out of band.
Workaround: Avoid GXX_ID (like GCS_ID) queries via out of band (through RPC) querying with ID of
device that is part of frame redirection
Feature: Field Escalation
Function: Fabric Services
Probability: Low
Found in Release: FOS6.3.1
Service Request ID: 627097
Where Else Fixed: FOS6.4.2 b GA
Defect ID: DEFECT000354348
Technical Severity: High
Summary: Not receiving the RAS log Cx-5021 message for front port partial credit loss on an EX-Port
Symptom: Customer will be unaware if EX_Ports are leaking credit.
Feature: 8G FCR
Function: FCR Daemon
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000356094
Technical Severity: High
Summary: IDLE not being sent after NOS - results in other issues and eventually causes G_Port.
Symptom: Customer simply notices that one side the ISL becomes a G_Port, while the peer remains
an E_Port.
Feature: Field Escalation
Function: Fabric Services
Probability: Low
Found in Release: FOS6.2.2
Service Request ID: 602057