Technical data
Fabric OS v7.0.1a Release Notes v1.0 Page 21 of 74
slot)
blades
384 16Gb ports +
QSFP ICLs
FC16-32, FC16-48
Port Blade
Not Supported
4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
384 8Gb ports +
QSFP ICLs
FC8-32E, FC8-48E
Port Blade
Not Supported
4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
Any combination
of 8Gb or 16Gb
ports and
intelligent blades
with QSFP ICLs
FC16-32, FC16-48,
FC8-64, FC8-32E,
FC8-48E, FS8-18,
FX8-24
Intelligent
Blade
/Combination
Not Supported
4 Power
Supplies
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
when any special
purpose blade are
installed
Table 4 Power Supply Requirements for DCX 8510-8
Notes:
1. When 2+2 power supply combination is used, the users are advised to configure the Fabric Watch setting for
switch marginal state to be two power supplies. Users can use the CLI switchstatuspolicyset to configure this
value if the current value is set to zero. In FOS v7.0.x, the default setting for the marginal state due to missing
power supplies is incorrectly set to zero (Defect 000349586), which will prevent Fabric Watch from generating
notifications when the switch enters the marginal state due to missing power supplies