Technical data
Fabric OS MIB Reference Manual 3-39
Publication Number: 53-0000521-08
Operation Group
3
fcFxPortPhysTable
OID 1.3.6.1.3.42.2.1.2.3
Description A table that contains, one entry for each Fx_Port in the fabric element, physical level
status and parameters of the Fx_Ports.
fcFxPortPhysEntry
OID 1.3.6.1.3.42.2.1.2.3.1
Description An entry containing physical level status and parameters of an Fx_Port.
Index fcFxPortPhysModuleIndex, fcFxPortPhysFxPortIndex
fcFxPortPhysModuleIndex
OID 1.3.6.1.3.42.2.1.2.3.1.1
Description Identifies the module containing the Fx_Port for which this entry contains
information.
fcFxPortPhysFxPortIndex
OID 1.3.6.1.3.42.2.1.2.3.1.2
Description Identifies the Fx_Port within the module. This number ranges from 1 to the value of
fcFeModulePortCapacity for the associated module. The value remains constant for
the identified Fx_Port until the module is reinitialized.
fcFxPortPhysAdminStatus
OID 1.3.6.1.3.42.2.1.2.3.1.3
Description The desired state of the Fx_Port:
online (1) Place port online.
offline (2) Take port offline.
testing (3) Initiate test procedures.
A management station might place the Fx_Port in a desired state by setting this object
accordingly. The testing state (3) indicates that no operational frames can be passed.
When a fabric element initializes, all Fx_Ports start with fcFxPortPhysAdminStatus
in the offline state (2). As the result of either explicit management action or per
configuration information accessible by the fabric element,
fcFxPortPhysAdminStatus is then changed to either the online (1) or testing (3) states
or remains in the offline state (2).
fcFxPortPhysOperStatus
OID 1.3.6.1.3.42.2.1.2.3.1.4
Description The current operational status of the Fx_Port: