Technical data
Fabric OS MIB Reference Manual 3-17
Publication Number: 53-0000521-08
Error Group
3
Description A flag indicating whether the Fx_Port has agreed to support Class 3 sequential
delivery from the fabric login. This is only meaningful if Class 3 service has been
agreed to. Possible values are:
yes (1) The Fx_Port has agreed to support Class 3 sequential delivery from the
fabric login.
no (2) The Fx_Port has not agreed to support Class 3 sequential delivery from the
fabric login.
fcFxPortNxPortName
OID 1.3.6.1.2.1.75.1.2.3.1.10
Description The port name of the attached Nx_Port, if applicable. If the value of this object is
‘0000000000000000’H, this Fx_Port has no Nx_Port attached to it.
fcFxPortConnectedNxPort
OID 1.3.6.1.2.1.75.1.2.3.1.11
Description The address identifier of the destination Fx_Port with which this Fx_Port is currently
engaged in either a Class 1 or loop connection. If the value of this object is
‘000000’H, this Fx_Port is not engaged in a connection.
fcFxPortBbCreditModel
OID 1.3.6.1.2.1.75.1.2.3.1.12
Description Identifies the BB_Credit model used by the Fx_Port. The regular model refers to the
buffer-to-buffer flow control mechanism defined in FC-PH [1] used between the
F_Port and the N_Port. For FL_Ports, the alternate buffer-to-buffer flow control
mechanism as defined in FC-AL [4] is used between the FL_Port and any attached
NL_Ports.
Error Group
This group consists of tables that contain information about the various types of errors detected. The
management station might use the information in this group to determine the quality of the link between
the Fx_Port and its attached Nx_Port.
Implementation of this group is optional.
Fx_Port Error Table
This table contains counters recording numbers of errors detected since the management agent
reinitialized, one entry for each Fx_Port in the fabric element.
The first six columnar objects after the port index correspond to the counters in the link error status
block.