Technical data
Fabric OS MIB Reference Manual 8-25
Publication Number: 53-0000521-08
Connectivity Group
8
0 = unknown
1 = Loop
2 = Fabric
4 = SCSI
8 = TCP/IP
16 = VI
32 = FICON
connUnitPortNodeWwn
Not supported in Fabric OS v2.6.1.
OID 1.3.6.1.3.94.1.10.1.22
Description The node World Wide Name of the port, if applicable; otherwise, an empty string.
All related ports in within a group should have the same node WWN value. The
container is defined as the largest physical entity.
Example:
All ports on HBAs on a host will have the same node WWN. All ports on the
same storage subsystem will have the same node WWN.
This is in IEEE Extended format and the extension contains the internal port
number of each port.
Note The internal port number is 1 less than the port index. For example, if the switch has
WWN 10:00:00:60:69:10:02:18, then port number 0 and 6 have WWN
20:00:00:60:69:10:02:18 and 20:06:00:60:69:10:02:18, respectively. However, the
embedded port has WWN 10:00:00:60:69:10:02:18, the same as the switch.
connUnitPortHWState
Not supported in Fabric OS v2.6.1.
OID 1.3.6.1.3.94.1.10.1.23
Description The state of the port as detected by the hardware. Possible values are:
unknown (1)
failed (2) Port failed diagnostics (port_flt_state).
bypassed (3) FCAL bypass, loop only (not used).
active (4) Connected to a device (light and sync are present).
loopback (5) Port in ext loopback (loopback state).
txfault (6) Transmitter fault (bad GBIC).
noMedia (7) Media not installed (GBIC removed).
linkDown (8) Waiting for activity—rx sync (light with no sync).
Connectivity Unit Event Table
connUnitEventTable
OID 1.3.6.1.3.94.1.11