Technical data

Fabric OS MIB Reference Manual 5-43
Publication Number: 53-0000521-08
Fabric Watch Group
5
If the write operation sets the variable to 3 (swFwCustom), the following custom
configuration variables are used for the Fabric Watch classArea combination:
swFwCustUnit
swFwCustTimebase
swFwCustLow
swFwCustHigh
swFwCustBufSize
swFwWriteActVals
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.14
Description This applies or cancels the alarm value changes.
Note For a read operation, the return value is always swFwCancelWrite.
The following are the custom alarm variables that can be modified:
swFwCustChangedActs
swFwCustExceededActs
swFwCustBelowActs
swFwCustAboveActs
swFwCustInBetweenActs
Changes to these custom alarm variables can be saved by setting this variable to
swFwApplyWrite.
Changes to these custom alarm variables can be removed by setting this variable to
swFwCancelWrite.
swFwDefaultChangedActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.15
Description Default action matrix for changed event.
swFwDefaultExceededActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.16
Description Default action matrix for an exceeded event. The exceeded value might be either
above the high threshold or below the low threshold.
swFwDefaultBelowActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.17
Description Default action matrix for below event.