Technical data

5-42 Fabric OS MIB Reference Manual
Publication Number: 53-0000521-08
Fabric Watch Group
5
Example:
% C = environment (class), temperature (area).
% RPM = environment (class), fan (area).
swFwCustTimebase
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.9
Description A customizable polling period for the Fabric Watch classArea combination. For
example:
% swFwTbMin = port (class), link loss (area).
% swFwTbNone = environment (class), temperature (area).
swFwCustLow
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.10
Description A customizable low-threshold value for a Fabric Watch classArea combination.
swFwCustHigh
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.11
Description A customizable high-threshold value for a Fabric Watch classArea combination.
swFwCustBufSize
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.12
Description A customizable buffer size value for a Fabric Watch classArea combination.
swFwThLevel
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.13
Description swFwThLevel is used to point to the current level for classArea values. It is either
default or custom.
Note For a read operation, the return value is either 2 (swFwDefault) or 3 (swFwCustom).
1 (swFwReserved) is obsolete.
If the write operation sets the variable to 2 (swFwDefault), the following default
configuration variables are used for the Fabric Watch classArea combination:
swFwDefaultUnit
swFwDefaultTimebase
swFwDefaultLow
swFwDefaultHigh
swFwDefaultBufSize