Technical data

Fabric OS MIB Reference Manual 5-41
Publication Number: 53-0000521-08
Fabric Watch Group
5
Changes to these custom configuration variables can be saved by setting this variable
to swFwApplyWrite; they can be removed by setting this variable to
swFwCancelWrite.
swFwDefaultUnit
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.3
Description A default unit string name, used to identify the unit of measure for a Fabric Watch
classArea combination.
Example:
% C = environment (class), temperature (area).
% RPM = environment (class), fan (area).
swFwDefaultTimebase
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.4
Description A default polling period for the Fabric Watch classArea combination.
Example:
% swFwTbMin = port (class), link loss (area).
% swFwTbNone = environment (class), temperature (area).
swFwDefaultLow
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.5
Description A default low threshold value.
swFwDefaultHigh
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.6
Description A default high threshold value.
swFwDefaultBufSize
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.7
Description A default buffer size value.
swFwCustUnit
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.8
Description A customizable unit string name, used to identify the unit of measure for a Fabric
Watch classArea combination.