unknown (1) The status of the sensor is unknown.
faulty (2) The status of the sensor is faulty.
below-min (3) The sensor value is below the minimal threshold.
nominal (4) The status of the sensor is nominal.
above-max (5) The sensor value is above the maximum threshold.
absent (6) The sensor is missing.
Note See the following list for valid values:
% For Temperature, valid values include 3 (below-min), 4 (above-max), and 4
(nominal).
% For Fan, valid values include 3 (below-min), 4 (nominal), and 6 (absent).
% For Power Supply, valid values include 2 (faulty), 4 (nominal), and 6 (absent).
swSensorValue
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4
Description The current value (reading) of the sensor.
The value -2147483648 represents the maximum value of integer value; it also means
that the sensor does not have the capability to measure the actual value. In v2.0, the
temperature sensor value is in Celsius, the fan value is in RPM (revolutions per
minute), and the power supply sensor reading is unknown.
Note The unknown value -2147483648 indicates the maximum value of integer value.
swSensorInfo
OID 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5
Description Additional information on the sensor. It contains the sensor type and number, in
textual format; for example, Temp 3 or Fan 6.