Technical data

Fabric OS MIB Reference Manual 5-17
Publication Number: 53-0000521-08
System Group
5
Where:
v = deployment indicator
M = major version
m = minor version
f = software maintenance version
Example:
v4.4.0 (indicating FOS version 4.4.0)
swOperStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.7
Description The current operational status of the switch. Possible values are:
online (1) The switch is accessible by an external Fibre Channel port.
offline (2) The switch is not accessible.
testing (3) The switch is in a built-in test mode and is not accessible by an
external Fibre Channel port.
faulty (4) The switch is not operational.
swAdmStatus
OID 1.3.6.1.4.1.1588.2.1.1.1.1.8
Description The desired administrative status of the switch. A management station might place
the switch in a desired state by setting this object accordingly. Possible values are:
online (1) Set the switch to be accessible by an external FC port.
offline (2) Set the switch to be inaccessible.
testing (3) Set the switch to run the built-in test.
faulty (4) Set the switch to a “soft” faulty condition.
reboot (5) Set the chassis to reboot in 1 second.
fastboot (6) Set the chassis to fastboot in 1 second. Fastboot causes the
chassis to boot but omit the POST.
switchReboot (7) Set the current switch to reboot in 1 second.
Note When the switch is in faulty state, only two states can be set: faulty and reboot/
fastboot/switchReboot.
For the SilkWorm 3900, the testing (3), faulty (4), and switchReboot (7) values are
not applicable.
For the SilkWorm 4100, the testing (3), faulty (4), and switchReboot (7) values are
not applicable.
The switchReboot (7) value only applies to the SilkWorm 12000/24000.