Technical data
Fabric OS MIB Reference Manual 3-43
Publication Number: 53-0000521-08
Error Group
3
Description Identifies the BB_Credit model used by the Fx_Port. The regular model refers to the
buffer-to-buffer flow control mechanism defined in FC-PH [1] used between the
F_Port and the N_Port. For FL_Ports, the alternate buffer-to-buffer flow control
mechanism as defined in FC-AL [4] is used between the FL_Port and any attached
NL_Ports.
Error Group
This group consists of tables that contain information about the various types of errors detected. The
management station might use the information in this group to determine the quality of the link between
the Fx_Port and its attached Nx_Port.
Implementation of this group is optional.
Fx_Port Error Table
This table contains one entry for each Fx_Port in the fabric element, and counters recording numbers of
errors detected since the management agent reinitialized.
The first six columnar objects after the port index correspond to the counters in the Link ErrorStatus
Block.
fcFxPortErrorTable
OID 1.3.6.1.3.42.2.1.3.1
Description A table that contains one entry for each Fx_Port, and counters that record the numbers
of errors detected since the management agent reinitialized.
fcFxPortErrorEntry
OID 1.3.6.1.3.42.2.1.3.1.1
Description An entry containing error counters of an Fx_Port.
Index fcFxPortErrorModuleIndex, fcFxPortErrorFxPortIndex
fcFxPortErrorModuleIndex
OID 1.3.6.1.3.42.2.1.3.1.1.1
Description Identifies the module containing the Fx_Port for which this entry contains
information.
fcFxPortErrorFxPortIndex
OID 1.3.6.1.3.42.2.1.3.1.1.2
Description Identifies the Fx_Port within the module. This number ranges from 1 to the value of
fcFeModulePortCapacity for the associated module. The value remains constant for
the identified Fx_Port until the module is reinitialized.