Technical data
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Address Mode 0]
Index Port Address Media Speed State Proto
==================================================
0 0 460000 id N16 Online FC F-Port 20:05:00:11:0d:a8:01:00
1 1 460100 id N16 Online FC F-Port 20:01:00:11:0d:bb:01:00
2 2 460200 id N16 Online FC F-Port 20:03:00:11:0d:84:01:00
3 3 460300 id N16 Online FC F-Port 20:07:00:11:0d:26:01:00
4 4 460400 id N16 Online FC F-Port 10:00:8c:7c:ff:5c:c5:01
5 5 460500 id N16 Online FC F-Port 10:00:8c:7c:ff:58:4c:00
6 6 460600 id N16 Online FC F-Port 10:00:8c:7c:ff:5c:c9:01
7 7 460700 id N16 Online FC F-Port 10:00:8c:7c:ff:5c:bd:00
8 8 460800 -- N16 No_Module FC
9 9 460900 -- N16 No_Module FC
10 10 460a00 -- N16 No_Module FC
11 11 460b00 -- N16 No_Module FC
12 12 460c00 -- N16 No_Module FC
13 13 460d00 -- N16 No_Module FC
14 14 460e00 -- N16 No_Module FC
15 15 460f00 -- N16 No_Module FC
16 16 461000 -- N16 No_Module FC
17 17 461100 -- N16 No_Module FC
18 18 461200 -- N16 No_Module FC
19 19 461300 -- N16 No_Module FC
20 20 461400 -- N16 No_Module FC
21 21 461500 -- N16 No_Module FC
22 22 461600 -- N16 No_Module FC
23 23 461700 -- N16 No_Module FC
24 24 461800 -- -- Online VE VE-Port 10:00:00:05:1e:65:77:04 "sb_71" (upstream)
25 25 461900 -- -- Offline VE
26 26 461a00 -- -- Offline VE
27 27 461b00 -- -- Offline VE
28 28 461c00 -- -- Offline VE
29 29 461d00 -- -- Offline VE Disabled (10VE Mode)
30 30 461e00 -- -- Offline VE Disabled (10VE Mode)
31 31 461f00 -- -- Offline VE Disabled (10VE Mode)
32 32 462000 -- -- Offline VE Disabled (10VE Mode)
33 33 462100 -- -- Offline VE Disabled (10VE Mode)
34 34 462200 -- -- Offline VE
35 35 462300 -- -- Offline VE
36 36 462400 -- -- Offline VE
37 37 462500 -- -- Offline VE
38 38 462600 -- -- Offline VE
39 39 462700 -- -- Offline VE Disabled (10VE Mode)
40 40 462800 -- -- Offline VE Disabled (10VE Mode)
41 41 462900 -- -- Offline VE Disabled (10VE Mode)
42 42 462a00 -- -- Offline VE Disabled (10VE Mode)
43 43 462b00 -- -- Offline VE Disabled (10VE Mode)
ge0 -- 40G Online FCIP
ge1 -- 40G No_Module FCIP
ge2 -- 10G No_Sync FCIP
ge3 -- 10G Online FCIP
ge4 -- 10G No_Module FCIP
ge5 -- 10G No_Sync FCIP
ge6 -- 10G Online FCIP
ge7 -- 10G Online FCIP
ge8 -- 10G Online FCIP
ge9 -- 10G Online FCIP
ge10 -- 10G Online FCIP
ge11 -- 10G Online FCIP
ge12 -- 10G Online FCIP
ge13 -- 10G No_Module FCIP
ge14 -- 10G No_Module FCIP
ge15 -- 10G No_Module FCIP
ge16 -- 10G Online FCIP
ge17 -- 10G Online FCIP
4. Verify the correct operation of the switch in the fabric by entering the fabricShow command from the
workstation.
This command provides general information about the fabric.
5. Back up the switch configuration to an FTP server by entering the configUpload command and
following the prompts.
sb_70:admin> configupload
Protocol (scp, ftp, local) [ftp]:
Installing and Configuring the Switch
Brocade 7840 Extension Switch Hardware Reference Manual 29
53-1003127-02