Technical data

BCSM IN A NUTSHELL 2008
© 2008 Brocade Communications Systems, Incorporated.
Page 33 of 44
CASCADED DIRECTOR REQUIREMENTS FOR B-SERIES
Requires Secure Fabric OS License
Includes fabric binding, switch binding, and port binding security methods that prevent
unauthorized devices from joining a fabric
Switch Connection Control (SCC) Policy in Security Set
SCC policy is used to restrict which switches can join the fabric
Insistent Domain ID (IDID) must be set on all switches
Domain IDs need to be unique
If both switches have IDID set and the same Domain ID, the fabrics will not merge
Dynamic Load Sharing (DLS) should be set to Off.
In-Order Delivery (IOD) should be set to On.
The DLS setting is recommended in a FICON environment. It does not allow for recomputing of routes
when an F_Port or E_Port changes status. This reduces the number of channel error messages (interface-
control checks) generated by the channel subsystem when a change of status occurs in the switch.
The IOD setting is mandatory in a FICON environment. It ensures frames are delivered in order. When
frames are not delivered in order, they will be dropped by the switch.
ENABLING CUP
The CUP License must be installed
FICON Management Server (FMS) Mode must be enabled
With CUP License installed and FMS Mode enabled
CUP Port is activated: Frames w/ address ‘0xDDFE00’ are routed to the CPU (CUP port address)
and in-band CUP commands processed