CASCADED DIRECTOR REQUIREMENTS FOR B-SERIES
Requires Secure Fabric OS License
• Includes fabric binding, switch binding, and port binding security methods that prevent
unauthorized devices from joining a fabric
Switch Connection Control (SCC) Policy in Security Set
• SCC policy is used to restrict which switches can join the fabric
Insistent Domain ID (IDID) must be set on all switches
Domain IDs need to be unique
• If both switches have IDID set and the same Domain ID, the fabrics will not merge
Dynamic Load Sharing (DLS) should be set to Off.
In-Order Delivery (IOD) should be set to On.
The DLS setting is recommended in a FICON environment. It does not allow for recomputing of routes
when an F_Port or E_Port changes status. This reduces the number of channel error messages (interface-
control checks) generated by the channel subsystem when a change of status occurs in the switch.
The IOD setting is mandatory in a FICON environment. It ensures frames are delivered in order. When
frames are not delivered in order, they will be dropped by the switch.
ENABLING CUP
• The CUP License must be installed
• FICON Management Server (FMS) Mode must be enabled
With CUP License installed and FMS Mode enabled
• CUP Port is activated: Frames w/ address ‘0xDDFE00’ are routed to the CPU (CUP port address)
and in-band CUP commands processed