Technical data
BCSM IN A NUTSHELL 2008
© 2008 Brocade Communications Systems, Incorporated.
Page 21 of 44
For device sharing related issues, two commands are very useful. Use the switchshow command on the
edge fabrics to verify devices are online:
NDA-T01-48K:admin> switchshow | grep e-port -i
116 10 4 0a7400 id N2 Online E-Port 50:00:51:e3:78:a8:5e:0a "fcr_fd_4"
(downstream)(Trunk master)
117 10 5 0a7500 id N2 Online E-Port (Trunk port, master is Slot 10 Port 4 )
118 10 6 0a7600 id N2 Online E-Port (Trunk port, master is Slot 10 Port 4 )
<Truncated Output>
Use the cfgshow command on the edge fabrics to verify device connectivity:
NDA-T01-48K:admin> cfgshow
<Truncated Output>
Defined configuration:
zone: fabAzone b48_w2k; b48_disk1
zone: lsan_fabBB_fabA b48_disk1; b75_w2k
<Truncated Output>
Note: The zoneshow command will give the same information in slightly different format
FABRIC MERGE ERRORS
What are the
segmentation
symptoms?
Incompatible switch
parameters
Zoning conflict
Domain ID conflict
Start
Figure 3: Fabric Merge Troubleshooting Tree