FCIP tunnel issues
4
Displaying QoS prioritization for a circuit
The following example will display QoS prioritization for an FCIP circuit on a 7800 switch.
switch:admin> portshow fcipcircuit 20 1 --perf --qos
For details of command syntax and output examples, refer to the Fabric OS Command Reference
Manual.
Displaying FCIP tunnel information (FR4-18i blade)
You can use the portShow fcipTunnel command to view the performance statistics and monitor the
behavior of an online FCIP tunnel. To view detailed fcipTunnel statistics, you must specify either the
-perf or -params options. The command syntax is as follows.
portShow fciptunnel [slot]/ge0|ge1 all|tunnel ID -perf -params
The following example shows the portCmd fcipTunnel with the -perf option to display performance
characteristics of tunnel 0.
switch:admin06> portshow fciptunnel 8/ge0 all —perf
For details of command syntax and output examples, refer to the Fabric OS Command Reference
Manual.
The following example shows the portCmd fcipTunnel with the parameters options to display the
parameters of tunnel 0:
switch:admin06> portshow fciptunnel 8/ge0 0 —params
For details of command syntax and output examples, refer to the Fabric OS Command Reference
Manual.
FCIP tunnel issues
The following are common FCIP tunnel issues and recommended actions for you to follow to fix the
issue.
NOTE
The portshow -perf and - params options can be applied only to the FR4-18i blade.
Symptom FCIP tunnel does not come Online.
Probable cause and recommended action
Confirm the following steps.
1. Confirm GE port is online.
portshow ge1
Eth Mac Address: 00.05.1e.37.93.06
Port State: 1 Online
Port Phys: 6 In_Sync
Port Flags: 0x3 PRESENT ACTIVE
Port Speed: 1G