Spec Sheet

Main Controls (Cont’d)
VC0191
It is the perfect wall control to manage the humidity percentage in the house. It features an
integrated humidity sensor to support the humidity level selected, which allows continuous comfort
even in the changing seasons.
INT: 20 min in MIN speed continuous exchange ventilation and 40 min in standby or
recirculation (if available) modes as per selected confi guration.
CONT: MIN speed (light LED indicator) continuous exchange ventilation.
MAX speed (dark LED indicator) continuous exchange ventilation.
DEHUM: Select from 30% to 55% RH. If the set point is exceeded, the system will operate
in MAX speed until the set point is reached. The dehumidistat will deactivate if outside
temperature exceeds 75°F (24°C).
The indicator lights up when fi lter maintenance is required and the indicator fl ashes
when a system error is detected.
Part no. VTDEHUMW
DEHUMIDISTAT
VC0184
It is designed to make customer’s life easier. All basic features as well as the most popular modes
are included with this wall control.
CONT: MIN, MED or MAX speed continuous exchange ventilation.
AUTO
AUTO: The system will operate according to outdoor temperature.
The indicator lights up when fi lter maintenance is required and the indicator fl ashes
when a system error is detected.
Part no. VAUTOW
RECIRC (if available): Recirculate air inside the house at MAX speed.
TURBO: 4-hour MAX speed exchange ventilation then comes back to its previous mode.
AUTOMATIC
INT: 20 min in MIN speed continuous exchange ventilation and 40 min in standby or
recirculation (if available) modes as per selected confi guration.
STB
Standby mode
STB
Standby mode