CENTRAL VACUUM POWER UNIT ! HOUSEHOLD TYPE ! CX450 & CXKIT450A MODEL NO. SFDB-DA AB0020 HOMEOWNERS OPERATING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Broan-NuTone Canada Inc.; Mississauga, Ontario www.broan.ca 888-882-7626 To register this product, visit www.broan.ca 30042423 Rev.
IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE. When using an electric appliance, basic precautions should always be followed, including the following: WARNING ! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY: • Do not use on wet surfaces or outdoors. • Do not allow to be used as a toy. Close attention is necessary when used by or near children. • Use only as described in this manual. Use only manufacturer's recommended attachments.
1. OPERATION The power unit is located away from the everyday living areas of your home — usually in the garage, basement, or utility room. Through a network of strong, lightweight tubing, the power unit connects to inlets strategically placed throughout your home. When you are ready to clean, attach the wand and cleaning tool onto the end of the hose. Open the inlet cover and insert the end of the hose into the inlet. Use the ON/OFF switch on the hose handle* to activate the power unit.
. DETAILED VIEW ROCKER EXHAUST SWITCH SECONDARY INLET FILTER VACUUM DISPOSABLE CHAMBER INLET CHAMBER OUTLET BAG ADAPTER LATCH BAG DEBRIS PAIL AL0003 5. BAG REPLACEMENT 1. To remove the disposable bag, release both latches on sides of the unit by pulling out and then pushing up. Remove the pail from unit. Grasp the edges of the bags’ collar and pull down. The bag will slide off easily. Do not pull on the bag. 2. Unfold new bag. 3.
6. PERMANENT FILTER (OPTIONAL) The optional permanent filter can be used with or without the disposable bag. This filter protects the motor and stops small particles from escaping to the outside of the power unit wihout the need to replace it. The filter can be removed by means of a pull-tab for cleaning (if need be). Be sure to reinstall properly. Appropriate location is critical to insure proper protection of the motor. 6.
7. HOW TO EMPTY DEBRIS PAIL To empty the debris pail, release both latches on sides of the unit by pulling out and then pushing up. Holding the pail by the latches, lower it from unit. Carry pail to trash receptacle and dispose of debris. Put the pail back in its place. 8. SECONDARY FILTER A secondary safety filter, located at the top of the vacuum chamber provides protection against dirt being pulled into the motor if the disposable bag or permanent filter should accidentally be torn.
9. POWER UNIT INSTALLATION 9.1 LOCATING THE POWER UNIT • Locate the power unit away from the general living area in an accessible location for cleaning and maintenance. • Locate the power unit within 6 feet of a grounded electrical outlet. The power unit requires a 120 VAC power source. • Do not locate the power unit close to a source of extreme heat (i.e.: water heater) or in an area with a high ambient temperature (i.e.: attic, furnace room).
9. POWER UNIT INSTALLATION (CONT’D) RETAINING SCREW LOCATIONS 4. Use the mounting bracket as a template to mark the position of its screws. Drill the upper and lower screw holes into the stud using a 3/16” drill bit. MOUNTING BRACKET CENTER OPENING AA0006 5. Using a Phillips screwdriver, secure the mounting bracket to the wall with 2 no. 14 x 2” screws (included). Make sure that the bracket is tight against the wall. 6.
10. GROUNDING INSTRUCTIONS ! WARNING Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance — if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance must be grounded.
11. ACCESSORY KIT MODEL CX450 CXKIT450A ACCESSORY KIT NOT included Included Accessory kit includes: • Multi-Surface tool for carpet, tile, wood and ceramic. AA0007 • 30’ Low-voltage crushproof hose with 360° rotating handle. Deluxe hose hanger included. AA0008 • Standard tool set: 12” wide hard floor brush with swivel neck. Aluminum ratchet telescopic wand; from a collapsed length of 22” to an extended length of 39”. Natural bristle upholstery tool. Square faced dusting brush.
12. TROUBLESHOOTING GUIDE PROBLEMS POSSIBLE 1. Loss or decrease of vacuum occurs. • The plastic cap is not installed on • Place the included plastic cap on the unused inlet. the unused inlet opening. • Debris pail or disposable bag is • Change disposable bag or empty completely full. debris pail as described on page 4. NOTE: Clean secondary filter if necessary. • Obstruction in the hose.
BROAN-NUTONE CANADA INC. CENTRAL VACUUM POWER UNIT LIMITED LIFETIME WARRANTY Broan-NuTone Canada warrants to the original consumer purchaser that its central vacuum power unit will be free from defects in materials and workmanship for as long as you own your home in which it was originally installed with the exception of the motor and electronic components which will be warranted for three (3) years. The first year of this warranty covers the parts and labor in an authorized service center.