PREPARE THE CABINET (CONTD)
7. Measure the distance between both bottom bracket
edges (F) (FIG. 11). The table below shows the approriate
distance needed.
NARROW EDGE WIDE EDGE
F
From 19-3/8” to
< 19-9/16”
F
From 19-9/16” to
19-13/16”
If the measured distance needs to be shortened, screw two
no. 8-32 x 1/4” machine screws, in each bottom embossed
cabinet brackets hole; this will slightly bend the bottom part
of the brackets (FIG. 12). Screw both brackets until the
appropriate distance is obtained.
""
"
3/4"
FIG. 13
CABINET BACK WALL
CABINET BOTTOM
HORIZONTAL EXHAUST INSTALLATION ONLY (ALL UNITS)
This powerpack insert is factory shipped to exhaust vertically;
however, it is possible to make it exhaust horizontally (3¼” x 10”
ducting only).
8. Cut the hole for the horizontal exhaust through the back
wall of the cabinet using the dimensions shown. (FIG. 13).