Specification Sheet
BROAN
TM
ERVS100
Part no. ERVS100S
65-105 CFM (0.4 in. w.g.)
VB0198
THE FRESH AIR SOLUTION FOR SOUTHERN REGIONS
The Broan ERVS100 is an effective, balanced ventilation solution
designed specifically for homes in southern regions. The ERVS100
provides a continuous supply of fresh air to the home while
exhausting stale air and polluants. Plus it manages excess
moisture making it a centerpiece for tightly-constructed, energy
efficient homes in hot and humid or dry climates.
• 65 to 105 CFM at 0.4 in. w.g;
• Energy recovery core recovering up to 51% of the excess moisture
and up to 71% of the apparent heat or coolness;
• Built-in humidity sensor limiting the ventilation during periods of
excessive humidity to maintain a comfortable humidity level and
prevent risks of mold growth;
• Exclusive bracket system providing a faster and easier installation in
the ceiling, an attic, a small closet or a garage;
• Integrates with existing forced-air furnace ducting for easy
installation but runs independently to limit energy consumption
related to ventilation;
• Built-in damper on fresh air supply port to prevent outside air
in ltration when the unit is turned o ;
• Integrated control to the unit to easily set the unit at installation.
Control
Ventilation modes
POSITION MODE DESCRIPTION
SB* Standby Unit is o .
Unit can be activated in high speed by
the VB20W 20-minute
push-button control, if applicable
INT Intermittent Unit works 20 minutes per hour in low
speed.
Unit can be activated in high speed
by the VB20W 20-minute push-button
control, if applicable.
1 Low Speed Unit runs at 65 cfm.
Unit can be activated in high speed
by VB20W 20-minute push-button, if
applicable.
2 High Speed Unit runs at 105 cfm.
Unit can be activated in high speed
by the VB20W 20-minute push-button
control, if applicable.
REPAIRS AND MAINTENANCE
All parts requiring maintenance can be removed in less than 5 minutes
allowing easy access for repairs. The PSC motors are permanently
lubricated.
WARRANTY
The BROAN
TM
ERVS100 is protected by a 5-year warranty on parts only.
The energy core is covered by a 5-year warranty, with the original proof
of purchase.
Relative humidity limit
The ERVS100 monitors the outside air conditions (temperature and
humidity level) every 10 minutes with a built-in sensor. When the
outside conditions are above the set limits, the unit will limit the
ventilation to 10 minutes per hour and come back to its previous
setting when the conditions get back to the set limit. The accepted RH
limit varies in function of the outside conditions and can be adjusted
to 4 di erent positions:
Distributed air RH*
Position Description Outside
temp
<73°F
Outside
temp
≥73°F
OFF Relative humidity limit
is deactivated
--
+ Higher relative humidity limit Up to
60%
Up to
80%**
N Factory set relative humidity
limit
Up to
55%
Up tp
75%**
- Lower relative humidity limit Up to
50%
Up to
70%**
* The RH limit of distributed air is calculated at 75°F.
** When the outside temperature is equal or above 73°F, the
maximum relative humidity level accepted is higher considering
that the air conditionning will partly dehumidify the incoming
fresh air after it is distributed and mixed with the conditionned
inside air.
*Factory setting