Specification Sheet

ENERGY RECOVERY VENTILATOR
BROAN® ERV250 ECM
Part no. ERV250TE
50 to 241 CFM (0.4 in. w.g.)
THE FUTURE OF FRESH AIR
The whole home ventilation system is a centerpiece of today’s
energy- efficient homes. Broan introduces its new HE Series that
combines the best performance with the best energy efficiency to
provide fresher, purer air in your home at a lower overall operating
cost. That’s Pure Efficiency.
The ERV250 ECM is the perfect solution for mid to large size homes
in need for the most energy-efficient ventilation solution.
• Up to 241 CFM at 0.4 in. w.g.
High efficiency energy recovery core with a sensible recovery
efficiency of 75% at 32°F and 65% at -13°F
• German-made ECM* motors
• Minimal power consumption of 18 W and 3.6 CFM/Watt at 64 CFM
• Merv 6 grade filters and optional HEPA filtration
• Electronic balancing and no balancing dampers
*Electronically Commutated Motor.
REPAIRS AND MAINTENANCE
The ERV250 ECM high output ECM motors are permanently lubricated.
The electronic circuit board eliminates electromechanical parts,
reducing repair time to a minimum.
WARRANTY
The ERV250 ECM is protected by a 5- year warranty on parts only, except
for the energy recovery core, which is covered by a 10-year warranty,
with the original proof of purchase.
VB0236
Requirements and standards
Complies with the UL 1812 requirements regulating the installation
of Energy Recovery Ventilators
Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
Complies with CSA C444 requirements regulating the installation of
Energy Recovery Ventilators
Technical data was obtained from published results of tests relating
to CSA C439 Standards
• HVI certifi ed and ENERGY STAR®* qualifi ed
Available at:
Controls
The exclusive VT9W main wall control is the only compatible wall
control to be used with the ERV250 ECM.
At installation, use the VT9W main control to perform electronic
balancing, whitout balancing dampers!
Optional auxiliary controls also available; for
more details, refer to the
User Guide - Main and auxiliary wall controls available at www.broan.com.
Option
HEPA Filter 21996
Additional 0.3 in. w.g. static pressure at highest speed to be considered.
Refer to the HEPA filter instructions for more details.
Homeshield™ Defrosting System
DEFROST IN MINUTES / AIR EXCHANGE IN MINUTES
OUTDOOR
TEMPERATURE*
STANDARD DISCRETION PLUS
°C °F
C
ONTINUOUS
MODE
TURBO
FUNCTION
CONTINUOUS
MODE
TURBO
FUNCTION
CONTINUOUS
MODE
TURBO
FUNCTION
-27 and less -17 and less
10/25 10/20 18/25 18/20 15/20 15/15
-20 to -27 -4 to -17
8/28 8/23 16/28 16/23 12/20 12/15
-15 to -20 5 to -4
8/35 8/30 16/35 16/30 10/25 10/20
-10 to -15 14 to 5
8/45 8/40 16/45 16/40 10/30 10/25
WARMER
THAN -10
WARMER
THAN 14
NO DEFROST
* Outdoor temperature is read by a thermistor located inside the unit, next to fresh air
from outside port.
VF0064
STALE AIR
FROM
BUILDING
FILTERED AIR
TO BUILDING
Use the VT9W to choose one of the 3 defrost modes available, according
to your needs:
• Standard (factory set regular mode)
• Plus (extended defrost for colder areas)
Discretion (keeps the same speed when performing defrost
as performing ventilation)
The ERV250 ECM uses a unique
defrosting method. No negative
pressure is created by air
exhausted to the outdoors, as the
air is recirculated into the house,
helping to prevent any backdraft.
*This product earned the ENERGY STAR® by meeting strict energy effi ciency guidelines set by Natural Resources Canada and the EPA. It meets ENERGY STAR®
requirements only when used in Canada.