Specification Sheet
Available at:
84 to 140 CFM (0.4 in. w.g.) 53 to 105 CFM (0.4 in. w.g.)
67 to 120 CFM (0.4 in. w.g.) 40 to 80 CFM (0.4 in. w.g.)
Requirements and Standards
installation of Energy Recovery Ventilators
to ventilators
installation of Energy Recovery Ventilators
relating to CSA C439 Standards
The ERV140TE has been designed to be one of the most
energy-efficient ERV air exchangers available on the market.
Its innovative design incorporates high performance ECM*
motors which consume significantly less electricity. ERVs are
ideal for LEED®-certified residential projects and other
energy-efficient homes because they recover the heat or
coolness of the indoor air while helping to maintain comfortable
moisture levels inside the home.
and air conditioning during cooling season
consumption savings
and provide a cleaner appearance
measure and balance the air-flow
with practical straps
*Electronically Commutated Motor.
**For most climate zones.
REPAIRS AND MAINTENANCE
The ERV140TE’s high output ECM* motors are permanently
lubricated. The electronic circuit board eliminates
electromechanical parts, reducing repair time to a minimum.
WARRANTY
The ERV140TE unit is protected by a 2-year warranty on all
parts, and a 5-year warranty on the energy recovery core.
BROAN® ERV140TE
Part no. ERV140TE
VF0050
Controls
press on its push button, located under the unit, to activate
it. Press once for low speed, once again for high speed, and
once more to stop it.
Homeshield™ Defrosting System
The ERV140TE uses a unique defrosting method. No
negative pressure is created by air exhausted to the outside
as the air is recirculated into the house, helping to prevent
any backdraft.
Energy Recovery Core
Dimensions: 10” x 10” x 14.25”
(25.4 cm x 25.4 cm x 36.2 cm)
Exchange surface: 110 ft² (10.2 m²)
Weight: 20 lb (9.1 kg)
Material: Polymerized paper
Type: Cross Flow
Warranty: 5 year
S TALE AIR
FROM BUILDING
FILTERED AIR
TO BUILDING
OUTSIDE
TEMPERATURE
DEFROST CYCLE
DEFROSTING MIN./
OPERATING MIN.
ºC ºF
WARMER
THAN -10
WARMER
THAN 14
NO
DEFROST
-10 TO -27 14 TO -17
7/25
-27
&
LESS
-17
&
LESS
10/22
ENERGY
RECOVERY VENTILATOR
The New BROAN®
and Enviromentally-Friendly Energy
Recovery Ventilator
E
*
99528487A