Spec Sheet

Controls
Operating this unit is simple ! Once installed, press on the
push-button (on the front of the electrical box): 1st click start
at low speed, 2nd accelerate to high and 3rd, stop it.
For more convenience, this unit can also be controlled by an
optional main control. For a complete list of optional main and
auxiliary controls available, refer to the Wall Control Compatibility
Chart on last pages of wall controls speci cation sheet, available at
www.broan.com.
For more details about controls, refer to the Main and auxiliary
wall controls user guide, also available at www.broan.com.
Options
MERV 8  lters (part no. V65683)
Complete line of registers and di users
Compatible with the VTYIK1 transition
(see Ventilation Performance section)
Defrost Cycles (exhaust only defrost)
Choice of regular or extended defrost cycles, according to climatic
conditions.
To set extended defrost cycle, refer to the manual.
*Outdoor temperature is read by a thermistor located inside the unit,
next to the fresh air to building port.
Broan ERV130FL
Part no. ERV130FLS
66 to 129 CFM (0.4 in. w.g.)
VERSATILE AND DESIGNED WITH THE INSTALLER
IN MIND
The ERV130FL was created to respond to the builder’s and contractor’s
needs for new residential construction and regulatory requirements.
While reliable and durable, it is a cost-effective solution that can be
installed quickly and easily in medium to large-sized homes, thanks to
these features:
Energy recovery core with a sensible recovery e ciency of 75% at
32°F and 14°F
Pressure taps, balancing dampers and integrated hooks for quick,
e ective installation
No drain tubing required
Magnetic backdraft damper in the fresh air from outside and the
exhaust air from building ports
Flippable for greater installation  exibility
Can be suspended to the joists OR wall mounted using included
brackets
6’ power cord
Very quiet operation
ENERGY STAR® quali ed
REPAIRS AND MAINTENANCE
All parts of the ERV130FL can be removed in less than five minutes,
allowing direct access for easy repairs. The low power consumption
motor is permanently lubricated. Finally, the electronic circuit board
eliminates electromechanical parts, reducing repair time to a minimum.
WARRANTY
The ERV130FL is protected by a 5-year warranty on parts. The energy
recovery core is covered by a 5-year warranty, with the original proof
of purchase.
Available at:
ENERGY RECOVERY VENTILATOR
Energy Recovery Core
Dimensions: 12” x 12” x 12” (30.5 cm x 30.5 cm x 30.5 cm)
Material: Polymerized paper and aluminium
Type: Crossflow core
Warranty: 5 years
Requirements and Standards
Complies with the UL 1812 requirements regulating the installation
of Energy Recovery Ventilators
Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Complies with CSA F326 requirements regulating the installation of
Energy Recovery Ventilators
Technical data was obtained from published results of tests relating
to CSA C439 Standards
Can be used to comply with California Title 24 2019 Part 6
• HVI certi ed and ENERGY STAR® quali ed*
LOW SPEED DEFROST CYCLES
OUTDOOR TEMPERATURE*DEFROST IN MINUTES / AIR EXCHANGE IN MINUTES
°C °F REGULAR EXTENDED
WARMER THAN -12 WARMER THAN 10 NO DEFROST NO DEFROST
FROM
-12 TO -17 FROM 10 TO 1 6/40 12/35
FROM -17 TO -27 FROM 1 TO -17 6/20 12/20
-27 AND LESS -17 AND LESS 8/12 12/15
HIGH SPEED DEFROST CYCLES
OUTDOOR TEMPERATURE*DEFROST IN MINUTES / AIR EXCHANGE IN MINUTES
°C °F REGULAR EXTENDED
WARMER THAN -12 WARMER THAN 10 NO DEFROST NO DEFROST
FROM
-12 TO -17 FROM 10 TO 1 9/40 12/30
FROM -17 TO -27 FROM 1 TO -17 9/20 12/16
-27 AND LESS -17 AND LESS 9/12 12/12
VB0271
*This product earned the ENERGY STAR® by meeting strict energy e ciency guidelines set by Natural Resources Canada and the EPA. It meets ENERGY STAR®
requirements only when used in Canada.