Specification Sheet
Broan ErV100 PLUS
27 /8”
22”
18¼”
Ø 5” TYP.
6 ¼”
20”
23 /8”
9”
VK0087A
VD0328
VO0255
2 x
2 x
Exhaust air
to outside
Fresh air
from outside
Fresh air
to building
Exhaust air
from building
Removable terminal block to
ease wall control connection.
Use 4-wire, 22 AWG cable
(purchase separately).
120 volts, 0.8 A
3 ft. power cord
Integrated pressure taps
for balancing
Balancing dampers,
backdraft dampers
22 ga. steel
door
HorizontaL inStaLLation onLy
35 lb.
VQ0091A
UNIQUE 3 EASY STEPS FOR CEILING INSTALLATION
TOP VIEW
BOTTOM VIEW
• Optional chains and springs kit (sold separately,
part no. 61239, for wood or metal construction)
Bend integrated hooks
(2 on the same side)
and hang the unit.
Mount brackets to ceiling.
Clip the other side of
the unit to the brackets.
OR ALTERNATE INSTALLATION
• Integrated dampening device
to prevent vibration transmission
VH0
104
VH0
105
Example of a fully ducted installation
Example of a central draw point installation
Allow 24" x 30" minimum for access door.