Specification Sheet

ENERGY RECOVERY VENTILATOR
CONSTRUCTION
22 ga. galvanized steel housing
22 ga. pre-painted steel door
One-piece molded insulation shell,
(expanded polystyrene; UL 94 HF-1 certied)
Galvanized steel 5" diameter ports*
Steel door hinges and latches
Cold side ports with plastic ring; allow vapor barrier sealing
No drain required
*All units ports were created to be connected to ducts having a
minimum of 5” diameter, but if need be, they can be connected to
bigger sized ducts by using an appropriate transition (e.g.: 5” diameter
to 6” diameter transition).
MOTORS
Two high reliability, external rotor PSC motors, totally enclosed and
thermally protected
Backward blowers, can support high static pressure environment
FILTERS
Two washable 20 ppi reticulated polyester urethane foam lters,
UL 900 class 2 certied
Optional MERV 7 lter kit, part no.: 21030 (additional 0.1 in. w.g.
static pressure to be considered) (sold separately)
ERV CORE
Crossow aluminum-polymerized paper core, UL723 certied
Hydroscopic polymer exchange water by direct vapor transfer using
molecular transport without the need of condensation
Constructed of alternate layers of corrugated aluminum material
and polymeric bactericide dessiccant impregnated media; will not
promote growth of mold or bacteria
Unique rectangular ute design to provide very low pressure drop
values
Controls
For a complete list of optional main and auxiliary controls available,
refer to the Wall Control Compatibility Chart on last pages of wall
controls specication sheet, available at www.broan.com.
For more details about controls, refer to the Main and auxiliary wall
controls user guide, also available at www.broan.com.
Removable terminal block included for quicker low voltage control
connections
LED indicator shows error codes
Unit must be permanently energized, no control should be installed
on power supply of unit
Air Flow
Pressure taps and balancing chart to allow easier balancing of the
unit
Integrated balancing dampers in cold supply and cold exhaust ports
Integrated motorized damper adjacent to the cold supply port
Integrated backdraft damper in cold exhaust port
Defrosting System
Equipped with Homeshield™ defrosting system: recirculation defrost
cycle to maintain balanced air pressure in the dwelling unit
A switch on ERV unit allows 3 quick-access defrost modes, a LED
shows which defrost mode has been chosen:
- Standard (factory set regular mode)
- Plus (extended defrost for colder areas)
- Discretion (keeps the same speed when performing defrost as
performing ventilation)
Requirements and standards
HVI certified
ENERGY STAR® qualified
Complies with the UL 1812 requirements regulating the installation
of Energy Recovery Ventilators
Complies with the CSA C22.2 no. 113 Standard
applicable to ventilators
Complies with CSA C444 requirements regulating
the installation of Energy Recovery Ventilators
Defrost CyCles
outsiDe temperature* Defrost in minutes / air exChange in minutes
°C °F stanDarD plus DisCretion
Warmer than -10 Warmer than 14 no defrost no defrost no defrost
from
-10 to -15 from 14 to 5 8/50 10/30 16/50
from -15 to -27 from 5 to -17 8/25 10/20 16/25
-27 and less -17 and less 10/22 10/15 20/22
Warranty
The Broan ERV100 PLUS is protected by a 5-year warranty on parts
only, with the original proof of purchase.
* Outside temperature is read by a thermistor located inside the unit,
next to fresh air from outside port.
VB0243
This product earned the ENERGY STAR® by meeting strict energy eciency guidelines set by Natural Resources Canada and the US EPA. It meets ENERGY STAR
requirements only when used in Canada.
BROAN ERV100 PLUS
Part no. ERV100SP
Low speed: 50 CFM (0.2 in. w.g.), selectable 65 CFM
High speed: 100 CFM (0.4 in. w.g.), selectable 85 CFM