Spec Sheet
ENERGY RECOVERY VENTILATOR
CONSTRUCTION
• 22 ga. galvanized steel housing
• 22 ga. pre-painted steel door
• One-piece molded insulation shell,
(expanded polystyrene; UL 94 HF-1 certi ed)
• Galvanized steel 5" diameter ports*
• Steel door hinges and latches
• Cold side ports with plastic ring; allow vapor barrier sealing
• No drain required
• Included installation brackets
*All units ports were created to be connected to ducts having a
minimum of 5” diameter, but if need be, they can be connected to
bigger sized ducts by using an appropriate transition (e.g.: 5” diameter
to 6” diameter transition).
MOTORS
• Two high reliability, external rotor PSC motors, totally enclosed and
thermally protected
• Backward blowers, can support high static pressure environment
FILTERS
• Two washable 20 ppi reticulated polyester urethane foam lters,
UL 900 class 2 certi ed
• Optional MERV 8 lter kit, part no. V21030 (additional 0.1 in. w.g.
static pressure to be considered) (sold separately)
ERV CORE
• Cross ow aluminum-polymerized paper core, UL723 certi ed
• Hydroscopic polymer exchange water by direct vapor transfer using
molecular transport without the need of condensation
• Constructed of alternate layers of corrugated aluminum material
and polymeric bactericide dessiccant impregnated media; will not
promote growth of mold or bacteria
• Unique rectangular ute design to provide very low pressure drop
values
Controls
• The ERV100SP unit must be controlled by a main wall control (not
included). For a complete list of optional main and auxiliary controls
available, refer to the Wall Control Compatibility Chart on last pages
of wall controls speci cation sheet, available at www.broan.com.
• For more details about controls, refer to the Main and auxiliary wall
controls user guide, also available at www.broan.com.
• Removable terminal block included for quicker low voltage control
connections
• LED indicator shows error codes
• Unit must be permanently energized, no control should be installed
on power supply of unit
Air Flow
• Pressure taps and balancing chart to allow easier balancing of the
unit
• Integrated balancing dampers in cold supply and cold exhaust ports
• Integrated motorized damper adjacent to the cold supply port
• Integrated backdraft damper in cold exhaust port
Defrosting System
• Equipped with Homeshield™ defrosting system: recirculation defrost
cycle to maintain balanced air pressure in the dwelling unit
• A switch on ERV unit allows 3 quick-access defrost modes, a LED
shows which defrost mode has been chosen:
- Standard (factory set regular mode)
- Plus (extended defrost for colder areas)
- Discretion (keeps the same speed when performing defrost as
performing ventilation)
Requirements and standards
• HVI certi ed
• ENERGY STAR® quali ed
• Complies with the UL 1812 requirements regulating the installation
of Energy Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Complies with CSA F326 requirements
regulating the installation
of Energy Recovery Ventilators
DEFROST CYCLES
OUTDOOR TEMPERATURE*DEFROST IN MINUTES / AIR EXCHANGE IN MINUTES
°C °F STANDARD PLUS DISCRETION
WARMER THAN -10 WARMER THAN 14 NO DEFROST NO DEFROST NO DEFROST
FROM
-10 TO -15 FROM 14 TO 5 8/50 10/30 16/50
FROM -15 TO -27 FROM 5 TO -17 8/25 10/20 16/25
-27 AND LESS -17 AND LESS 10/22 10/15 20/22
Warranty
The Broan ERV100 PLUS is protected by a 5-year warranty on parts
only, with the original proof of purchase.
* Outdoor temperature is read by a thermistor located inside the unit,
next to fresh air from outdoor port.
VB0265
This product earned the ENERGY STAR® by meeting strict energy e ciency guidelines set by Natural Resources Canada and the US EPA. It meets ENERGY STAR
requirements only when used in Canada.
BROAN ERV100 PLUS
Part no. ERV100SP
Low speed: 50 CFM (0.2 in. w.g.), selectable 65 CFM
High speed: 100 CFM (0.4 in. w.g.), selectable 85 CFM