Specification Sheet
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
SPECIFICATION SHEET
80F 99044542A
FEATURES
•
Cost-effective solution to dilute contaminants inside
the house by continually exchanging stale polluted air
with fresh outdoor air.
•
Continuous background ventilation with 30-55
cfm of fresh air / Improves air quality by reducing
contaminant concentration levels.
•
It is the minimal requirement for improved indoor air
quality and continuous air exchange, and for reducing
excess humidity (depending on outside conditions).
•
Ideal for houses that already have a bath fan.
•
Smart Electronics board / Advanced smart
temperature circuitry will set the percentage of air
mixture to optimize comfort levels in case of extreme
temperatures (below 23°F and above 74°F).
•
Easy-to-use wall switch included with unit / Better
unit control with settings; off, normal, boost, and
recirculation modes. Includes fresh air indicator and
lter maintenance indicator.
AE60
FRESH AIR SYSTEM
GENERAL SPECIFICATIONS
•
For houses up to 2,000 sq. ft.
•
160 cfm (including 30 cfm of fresh air) to 185 cfm
(including 55 cfm of fresh air)
•
Voltage: 120 VAC
•
Frequency: 60 Hz
•
Dimensions: 23” x 12.25” x 15”
•
Weight: 40 lbs
•
Shipping Weight: 45 lbs
•
Warranty: 2 years on parts
•
HVI Rated of air ow: 56 cfm
•
Power Consumed (max): 140 Watts
•
Supply air duct connections: Stale, 4” or 5”; Fresh: 6”
•
Exhaust air duct connections: Stale, 6”; Fresh, 4” or 5”
•
Filter: 1 mesh lter
•
Cabinet: 20 ga. Pre-painted steel
•
Mounting: Suspension by chains and springs
•
Wall control modes: Off, Normal, Boost, and
Recirculation
•
Power: 140 Watts
•
Current: 1.2 Amps
•
Continuous duty, permanently lubricated motors
•
36” power cord
Whole-house Air Exchanger
Filter Maintenance
Fresh Air
Recirculation
Boost
Normal
Off
Reset Filter
Filter Maintenance
Fresh Air
Recirculation
Boost
Normal
Off
Reset Filter


