Specification Sheet
Broan Hartford, Wisconsin www.broan.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
SPECIFICATION SHEET
81K 1100250B
MODEL AE50110DCSL
FLEX DC
TM
SERIES
HUMIDITY SENSING FAN / LIGHT
A modern-styled, high performance fan, with sensing circuitry,
that "knows" when to ventilate the room.
FEATURES
BLOWER:
• Plug-in, permanently lubricated, brushless DC motor -
engineered for continuous operation
• Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
• Low RPM for quiet operation
• Selectable settings of 50, 80 or 110 CFM
HOUSING:
• Rugged, 26 gauge, galvanized steel construction
• Polymeric, 4” damper / duct connector with tapered sleeve
and no metallic clatter
• 5-3/4” height allows for 2” x 6” ceiling installations
• Sturdy, easy, four-point mounting directly to joist
• Optional snap-on flange kit
GRILLE:
• Polymeric construction
• Innovative design - the result of extensive research with
designers and consumers
• 11-Watt integrated LED lighting for energy efficiency
• 3500K color temperature provides soft white light - ideal for
bathroom illumination
• LED lasts up to 25,000 hours for maintenance-free
convenience
DIMMING CONTROLS :
• For a list of compatible dimming controls, see the
RESOURCES link for Model AE50-110DCSL at
www.broan.com
• Each application is unique and various factors such as
load, common neutrals or other electrical products on the
circuit can, in certain instances, cause variance in system
performance
AUTOMATIC CONTROL:
• Humidity control automatically turns fan ON when
either of these conditions is detected:
- a rapid to moderate (user adjustable) increase of
humidity
- humidity above user-adjustable set-point (50%-80%
RH)
• Two wire manual operation for odor control - Turns fan
ON when power line through wall switch is cycled ON,
OFF and back ON
• Remains ON for a user-adjustable 5 to 60 minutes
after humidity has stabilized and is below set-point or
after manually initiated through power line cycling
• Saves energy because unit runs only for the time
required. A unit controlled with a wall timer may keep
fan ON longer than required or turn it OFF before
room is sufficiently ventilated
U.L. Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit (ceiling
mount only)
U.L. Listed for use in insulated ceilings (Type I.C.)
3-Year Warranty
JA8-2019
• Dimmer model numbers vary slightly depending on
color, packaging type, etc. such that variations of
model numbers may be suitable. Consult dimming
system manufacturer for additional support in
operation