Installation Guide

ROCKER SWITCH
2. Install at least a 2¾” deep switch box
for 14 AWG wire or at least a 3½”
deep switch box for 12 AWG wire.
3. Connect cables to switch box and
appliance (load) using appropriate
connectors. Provide 6” leads inside
box and appliance and strip ends
5/8”. (Use strip gauge on back of
switch.)
4. Make electrical connections follow-
ing diagram on back. Make sure both
the control and the appliance are
properly grounded.
For side-wiring:
Loop wires clockwise, ¾ turn around
terminal screws and tighten securely.
For push-in wiring: Insert straight
ends of wires into appropriate push-
in wiring holes. Do no insert wires into
release slots.
5. Tuck wires into switch box and fas-
ten the control to box using attached
screws.
6. Fasten the switch plate to the con-
trol using the short screws from the
parts bag.
WARNING
All electrical work must be done in
accordance with local codes, ordi-
nances, or National Electrical Code
as applicable. FOR SAFETY, THIS
PRODUCT MUST BE GROUNDED.
If you are unfamiliar with methods of
installing electrical wiring, secure the
services of a qualified electrician.
Turn off power and lock out service
panel before installing, wiring, or ser-
vicing this product.
To prevent serious injury from elec-
trical shock or damage to electrical
components - DO NOT WIRE HOT!
Use with copper wire only.
Warranty void if miswired.
INSTALLATION
1. Turn off power and lock out service
panel before wiring the control.