Installation Guide
INSTALLATION INSTRUCTIONS
NOTE: ALL ELECTRICAL CONNECTIONS MUST BE IN
ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMIL-
IAR WITH METHODS OF INSTALLING ELECTRICAL WIR-
ING, HAVE A QUALIFIED ELECTRICIAN DO IT FOR YOU.
1. Turn off power and lock out service panel before wiring the
control.
2. Install at least 2½" deep switch box for 14-gauge wire or at
least 2¾" deep switch box for 12-gauge wire.
3. Connect cables to switch box and appliance using appropriate
connectors. Provide 6” leads inside box and appliance.
4. Make electrical connections following diagram on back. Use
wire nuts. Make sure both the control and the appliance are
properly grounded.
5. Tuck wires into switch box and fasten the control to box using
attached screws.
6. Fasten the switch plate to the control using the short screws
from the parts bag.
3 AMP / 120 VAC, ELECTRONIC SPEED CONTROL
WARNING
• All electrical work must be done in accordance with local
codes, ordinances, or National Electrical Code as appli-
cable. FOR SAFETY, THIS PRODUCT MUST BE
GROUNDED. If you are unfamiliar with methods of install-
ing electrical wiring, secure the services of a qualified
electrician.
• Turn off power and lock out service panel before installing,
wiring, or servicing this product.
• To prevent serious injury from electrical shock or damage
to electrical components – DO NOT WIRE HOT!
• Do not use with impedance protected motor unless spe-
cifically designed for use with electronic speed control.
• This control may only be used with a thermally protected
shaded pole or permanent split capacitor motor with a
nameplate rating up to 3.0 AMPS @ 120 VAC.
• Warranty is void if miswired.