Technical data

7. CONTROLS (CONT’D)
7.6 OPERATING ACCGSC3 CONTROLLER
7.6.1 ACCGSC3 C
ONTROLLER DESCRIPTION
7.6.2 USING ACCGSC3 CONTROLLER
• OFF: To stop the unit, slide the button on this position.
• LOW VENTILATION: For a day-to-day usage, slide the button on this position.
The unit then will operate on low speed, providing 70 cfm.
• H
IGH VENTILATION: For a high speed operation, slide the button on this position.
Generally used when more ventilation is required, such as parties, smokers, or for a 6-bedroom house.
This mode provides 105 cfm.
• RECIRCULATION: For a low speed operation, without exchanging air with the outside, slide the button on this position.
This mode is recommended in high humidity days (rain, heat wave). Also, use it when the outside temperature is
extremely cold and/or the inside air is too dry. It can be used also to recirculate the heat coming from a wood
stove throughout the house, or the fresh air from a cooling system.
Off
Recirculation
Reset Filter
Filter Maintenance
Fresh air
High Ventilation
Low Ventilation
VC0060
FILTER MAINTENANCE
INDICATOR:
FLASHES WHEN IT IS TIME TO
REPLACE PREFILTER AND WASH
CORE AND CORE FILTERS
.
LED STAYS LIT WHEN IT IS
TIME TO REPLACE FILTER AND
PREFILTER AND CLEAN CORE
AND CORE FILTERS
.
- 31 -
Low VENTILATION INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH
IS ON LOW VENTILATION
POSITION.UNIT IS OPERATING
ON NORMAL SPEED
.
RESET FILTER HOLE:
O
NCE THE MAINTENANCE DONE, RESET THE FILTER MAINTENANCE INDICATOR BY CAREFULLY
INSERTING A SMALL ROD (EG: PAPER CLIP) IN THE RESET FILTER HOLE, FOR 1 SECOND.
THE FILTER MAINTENANCE INDICATOR WILL TURN OFF.REFER TO THE FILTER MAINTENANCE
RECOMMENDATIONS IN SECTION 8.
FRESH AIR INDICATOR:
LIGHTS UP WHEN SLIDE
SWITCH IS ON NORMAL
VENTILATION OR BOOST
VENTILATION POSITION.
HIGH VENTILATION INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH
IS ON HIGH VENTILATION
POSITION.UNIT IS OPERATING
ON HIGH SPEED.
RECIRCULATION INDICATOR:
LIGHTS UP WHEN SLIDE
SWITCH IS ON
RECIRCULATION.UNIT IS
OPERATING ON LOW SPEED.