Technical data
7.4 INSTALLATION OF THE WALL CONTROLLERS (BOTH MODELS) (CONT’D)
10. Reinstall the side door on the electrical box and install the 8’’ oval port on the unit.
11. Route the wire through its channel and reinstall the front panel on the unit.
See photo beside.
12. Plug the unit to the wall outlet.
NOTE: When using the wall controller, the main s
witch on the unit must always be positioned to NORMAL/REMOTE.
7. CONTROLS (CONT’D)
VD0089
- 30 -
7.5 OPERATING ACCGSC1 CONTROLLER
7.5.1 ACCGSC1 C
ONTROLLER DESCRIPTION
7.5.2 USING ACCGSC1 CONTROLLER
• OFF: To stop the unit, slide the button on this position.
• LOW: For a day-to-day usage, slide the button on this position.
The unit then will operate on low speed, providing 70 cfm.
• HIGH: For a high speed operation, slide the button on this position.
Generally used when more ventilation is required, such as parties, smokers, or for a 6-bedroom house.
This mode provides 105 cfm.
VC0059
High
Low
OFF
Reset Filter
Filter Maintenance
Power
OFF:
UNIT IS OFF.
POWER INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH
IS ON
LOW OR HIGH POSITION.
FILTER MAINTENANCE
INDICATOR
:
FLASHES EVERY MINUTE TO
INDICATE IT IS ON DUTY.
FLASHES EVERY SECOND WHEN
ITS TIME TO REPLACE
PREFILTER
.SEE SEMI-ANNUAL
MAINTENANCE IN SECTION 7.
LED STAYS LIT WHEN ITS TIME TO
REPLACE FILTER AND PREFILTER
.
Low:
U
NIT IS OPERATING ON
LOW SPEED.
RESET FILTER HOLE:
ONCE THE MAINTENANCE DONE, RESET THE FILTER
MAINTENANCE INDICATOR BY CAREFULLY INSERTING
A SMALL ROD
(EG: PAPER CLIP) IN THE RESET FILTER
HOLE, FOR 1 SECOND.THE FILTER MAINTENANCE
INDICATOR WILL TURN OFF
.REFER TO THE FILTER
MAINTENANCE RECOMMENDATIONS IN SECTION 8.
HIGH:
UNIT IS OPERATING ON
HIGH SPEED.