7.3 DIMENSIONS
Dimensions are the same for both models.
7.4 INSTALLATION OF THE WALL CONTROLLERS (BOTH MODELS)
1. Determine the more convenient location for the control.
2. Remove the controller cover plate (1). If you prefer to have your main control mounted on an
approved outlet box or an approved mounting bracket (not included), discard the backplate (2).
3. Route the control cable from the unit to the wall controller.
Use the provided cable (4-conductor, 24-gauge, Solid, UL Listed, CM type, 40’ long).
NOTE: For wall controller efficiency, the maximum wire length is 100’ (30.5 m). If needed, add another length of same wire type.
Use caution not to cross the wire colors or create any short.
4. Take one end of the provided cable and pass it through the wall control backplate (or outlet box or mounting bracket).
5. Splice back this end of the cable to access to the four wires. Remove the insulated
sleeve of each wire ends. Make a loop with each bare end wire to hook them to the
corresponding screw. Connect YELLOW wire to ‘’Y’’ screw, RED wire to “R’’ screw,
GREEN to “G’’ screw and BLACK to ‘’B’’ screw. See illustration beside.
VC0049
- 28 -
7. CONTROLS (CONT’D)
CAUTION
Never install more than one optional wall control per unit.
WARNING
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical shock or
damage of the wall control or electronic module inside the unit.
0
!
WARNING
To avoid risk of electrical shocks, never install another wire in the same electrical box than the one for the wall controller.
0
!
1
2
BLACK
wire
YELLOW
wire
GREEN
wire
RED
wire
WARNING
Make sure that the wires do not short circuit between themselves or by touching any other components on the wall controller.
0
!