Technical data
6. INSTALL THE UNIT (CONT’D)
6.7 INSTALLING AIRDUO™EXTERIOR HOOD* (GSVH1K, GSHH3K AND GSEH3K MODELS ONLY)
6.7.1. ASSEMBLING AIRDUO™EXTERIOR HOOD
AirDuo™ exterior hood requires assembly. Assemble the top metal screen, the plastic grille
and the bottom metal screen to AirDuo™ exterior hood. Use provided screws. See illustration
beside.
*Patent pending
6.7.2 LOCATING THE AIRDUO™EXTERIOR HOOD
The AirDuo™ exterior hood must be installed at a minimum distance of 18 inches (457 mm) above the
ground. See illustration beside.
6.7.3 CONNECTING TANDEM® TRANSITION TO AIRDUO™ EXTERIOR HOOD
1. Using a jig saw, cut a 6’’ diameter hole in the exterior wall and insert the Tandem®
transition through this hole.
2. Joint the end of the Tandem® transition to the rear of the exterior backplate. Secure
with 2 Xmas tree pins and seal properly with duct tape.
VO0024
VD0083
18''
(457 mm)
WARNING
Make sure this hood is at least 3 feet (0.9 m) away from any of the following:
• High efficiency furnace vent. • Any exhaust from a combustion source.
• Gas meter exhaust, gas barbecue-grill. • Garbage bin and any other source of contamination.
0
!
- 20 -
CAUTION
The exterior backplate must be installed with the word “TOP” pointing upward.
CAUTION
The Tandem® transition must be inserted in such a way that the
EXHAUST AIR TO OUTSIDE
duct will be located on the top.
VD0084
VD0085
Xmas tree pin
EXHAUST AIR TO OUTSIDE duct