Installation & Assembly
INSTALLATION MANUAL
INSTALLATION
19
Connect the Wiring
1 ] Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and 
GREEN or bare wire under GREEN ground screw.
!
 WARNING
Risk of electric shock. Electrical wiring must be done by qualifi ed 
personnel in accordance with all applicable codes and standards. 
Before connecting wires, switch power off at service panel and lock 
service disconnecting means to prevent power from being switched 
on accidentally.
!
 CAUTION
Ensure both tabs on inner top of hood are engaged in their corresponding slots in 
wiring cover. Also, take care not to pinch wires while reinstalling wiring cover.
SCREW
2 ] Reinstall wiring cover and attach it to the hood using its retaining screw.
TABS ON INNER 
TOP OF HOOD 
ENGAGED IN 
WIRING COVER 
SLOTS.
MOTOR 
GROUND 
WIRE
HOUSE
POWER CABLE
GROUND 
SCREW
Install the Filters
Ducted Installation Only:
Re-install grease filters removed in step 2 , page 9, under “Prepare the Hood”.
Non-ducted Installation Only:
Purchase two non-ducted filters from your local distributor or retailer (see product specification 
label for filter type). Attach the non-ducted filter(s) following instructions packed with the 
non-ducted filter.